Skip to main content
 

Digital Breast Tomosynthesis versus Digital Mammography Screening Performance on Successive Screening Rounds from the Breast Cancer Surveillance Consortium. Radiology

Abstract

BACKGROUND

Prior cross-sectional studies have observed that breast cancer screening with digital breast tomosynthesis (DBT) has a lower recall rate and higher cancer detection rate compared with digital mammography (DM).

PURPOSE

To evaluate breast cancer screening outcomes with DBT versus DM on successive screening rounds.

MATERIALS AND METHODS

In this retrospective cohort study, data from 58 breast imaging facilities in the Breast Cancer Surveillance Consortium were collected. Analysis included women aged 40-79 years undergoing DBT or DM screening from 2011 to 2020. Absolute differences in screening outcomes by modality and screening round were estimated during the study period by using generalized estimating equations with marginal standardization to adjust for differences in women’s risk characteristics across modality and round.

RESULTS

A total of 523 485 DBT examinations (mean age of women, 58.7 years ± 9.7 [SD]) and 1 008 123 DM examinations (mean age, 58.4 years ± 9.8) among 504 863 women were evaluated. DBT and DM recall rates decreased with successive screening round, but absolute recall rates in each round were significantly lower with DBT versus DM (round 1 difference, -3.3% [95% CI: -4.6, -2.1] [P < .001]; round 2 difference, -1.8% [95% CI: -2.9, -0.7] [P = .003]; round 3 or above difference, -1.2% [95% CI: -2.4, -0.1] [P = .03]). DBT had significantly higher cancer detection (difference, 0.6 per 1000 examinations [95% CI: 0.2, 1.1]; P = .009) compared with DM only for round 3 and above. There were no significant differences in interval cancer rate (round 1 difference, 0.00 per 1000 examinations [95% CI: -0.24, 0.30] [P = .96]; round 2 or above difference, 0.04 [95% CI: -0.19, 0.31] [P = .76]) or total advanced cancer rate (round 1 difference, 0.00 per 1000 examinations [95% CI: -0.15, 0.19] [P = .94]; round 2 or above difference, -0.06 [95% CI: -0.18, 0.11] [P = .43]).

CONCLUSION

DBT had lower recall rates and could help detect more cancers than DM across three screening rounds, with no difference in interval or advanced cancer rates.